Phone: 413-543-2257
Toll Free: 1-800-944-GRILL (4745)

"The Barbecue and Fireplace Toy Store"

Kozy Heat

Kozy Heat
Chaska 25
Features
Viewing Area: 21-7/8" x 12"
26,000 BTU/hr Input - NG
25,500 BTU/hr Input - LP
Electronic Ignition Pilot System
Ceramic Glass
Remote Control (full function),
Fan Kit
Refractory Brick Lining Upper Hood & Lower Grill
Co-Linear Air Duct - Accepts 3" Combustion Air / 3" Exhaust
Innovative vent connection system
Patented Log Design
Engineer-designed burner system
Minnesota Energy Code Compliant to 50 pascals
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
IPI
- ENERGUIDE P.4 NG/LP | 71.44% / 72.08%
- Steady State NG/LP | 77.58% / 78.17%
- AFUE % NG/LP | 69.79% / 70.33%
Efficiencies Glossary:
- P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
- Steady State Efficiency is a measure of how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
- Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including the cycling on and off time period.
Required Design Features
Screen Front
For options and pictures, look at the Chaska brochure under the Resources tab.
Optional Features
1 piece Shroud
Standard or Custom sizes

Chaska 25

Chaska 29
Features:
Comes in Log, Glass or Rock media
Viewing Area: 25-7/8" x 12-5/8"
BTU (Log & Rock) 30,000 (Glass) 25,500 (MV) 28,500
Electronic Ignition Pilot System
Co-Linear Air Duct –Accepts 3” Combustion Air / 3” Exhaust
Ceramic Glass
Fan Kit
Standard Ember Light Kit
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
Log and Rock
ENERGUIDE P.4 NG/LP | 72.27%/72.36%
Steady State NG/LP | 74%/74%
AFUE % NG/LP | 71%/72.12%
Glass
ENERGUIDE P.4 NG/LP | 60.8%/63.21%
Steady State NG/LP |72.21%/72.26%
AFUE % NG/LP | 66.62%/66.09%
MV
ENERGUIDE P.4 NG/LP |71.26%/71.33%
Steady State NG/LP | 74%/74%
AFUE % NG/LP |71%/72.12%
Efficiencies Glossary:
P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
Steady State Efficiency is a measure of how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including the cycling on and off time period.
Design Standard Features
Black Enamel Refractory
Standard on Chaska 29 Rock and Chaska 29 Glass only
Ember Light Kit
Standard on Chaska 29 Log and Chaska 29 Rock only
Accent Light Kit
Standard on Chaska 29 Glass only
Screen Front
For options and pictures, look at the Chaska brochure under the Resources tab.
Required Design Features
Glass Media Kit
For options and pictures, look at the Chaska brochure under the Resources tab.
Screen Front
For options and pictures, look at the Chaska brochure under the Resources tab.
Optional Features:
Black Enamel Lining
Optional for Chaska 29 Log
Required for Installation:
1 Piece Shroud ( Standard or custom size)

Chaska 29

Chaska 335S
Standard Features
Viewing area: 29 3/8” x 15-13/16”
36,000 BTU/hr Input NG
36,500 BTU/hr Input LP
Ceramic Glass
Fan Kit
Co-Linear Air Duct
Accepts 3” Combustion Air / 3”
Traditional Brick Lining
Upper Hood & Lower Grill Exhaust
Innovative vent connection system
High/Low Regulator Speed Control with Receptacle
Assembly Log Set Engineer-designed burner system
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
MV
- ENERGUIDE P.4 NG/LP | 65.74% / 66.63%
- Steady State NG/LP | 80% / 75%
- AFUE % NG/LP | 73.8% / 76.2%
Efficiencies Glossary:
- P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
- Steady State Efficiency is a measure of how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
- Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including the cycling on and off time period.
Required Design Features
Screen Front

Chaska 335S

Chaska 34
Features:
Comes in Log, Glass or Rock media
Viewing Area: 17 ½” x 29 7/8”
34,000 BTU/hr Input - NG
34,000 BTU/hr Input – LP
Electronic Ignition Pilot System
Co-Linear Air Duct - Accepts 3" Combustion Air / 3" Exhaust
Ceramic Glass
Fan Kit
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
IPI
- ENERGUIDE P.4 NG/LP | 73.22% / 76.49%
- Steady State NG/LP | 77% / 79%
- AFUE % NG/LP | 75% / 77%
Efficiencies Glossary:
- P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
- Steady State Efficiency is a measure of how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
- Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including the cycling on and off time period.
Design Standard Features
Curved Black Enamel lining
Standard in Chaska 34 Glass and Chaska 34 Rock only
Ember Light Kit
Standard in the Chaska 34 Log and Chaska 34 Rock only
Accent Light Kit
Standard in the Chaska 34 Glass only
Required Design Features
Glass Media Kit
For options and pictures, look at the Chaska brochure under the Resources tab.
Screen Front
For options and pictures, look at the Chaska brochure under the Resources tab.
Optional Features:
Black Enamel Refractory
Optional for Chaska 34 Log
Shroud Trim
Floor Protector - required if removing existing floor (see manual)
Required for Installation:
1 piece shroud
Standard or Custom size

Chaska 34

Nordik 29i
Features:
Viewing Area: 17-15/16" x 27-11/16"
32,000 BTU/hr Input NG
32,000 BTU/hr Input
Electronic Ignition Pilot System
Ceramic Glass
Fan Kit
Standard Ember Light Kit
Standard Top Light Kit
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
ENERGUIDE P.4 NG/LP | 70.11% / 70.54%
Steady State NG/LP | 71.84% /72.22%
AFUE % NG/LP | 71.56% / 72.15%
Efficiencies Glossary:
P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
Steady State Efficiency measures how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including cycling on and off time period.
Design Standard Features
Screen Front
For options and pictures, look at the Nordik brochure under the Manuals & Brochures tab.
Required Design Features
Traditional or Birch log set (Sold separately – one required for installation)
Screen Front
For options and pictures, look at the Nordik brochure under the Manuals & Brochures tab.
Optional Features:
Black Brick Refractory
Chicago Brick Refractory
Ledgestone Refractory
Herringbone Refractory
Black Glass Panels
Required for Installation:
1 Piece Shroud (Standard or custom size)

Nordik 29i

Nordik 34i
Features:
Viewing Area: 22-1/4”x 30-11/16”
40,000 BTU/hr Input NG
40,000 BTU/hr Input
Electronic Ignition Pilot System
Ceramic Glass
Fan Kit
Standard Ember Light Kit
Standard Top Light Kit
Certified to ANSI Z21.88 Vented Gas Heater
Efficiencies
ENERGUIDE P.4 NG/LP | 70.29% / 69.53%
Steady State NG/LP | 70.95% /71.08%
AFUE % NG/LP | 70.72% / 70.80%
Efficiencies Glossary:
P.4 Efficiency (ENERGUIDE) is an efficiency rating more recognized in Canada to measure annual fireplace efficiency.
Steady State Efficiency measures how efficiently your fireplace converts fuel to heat once it is warmed up and operating at a steady temperature.
Annual Fuel Utilization Efficiency (AFUE) is a measurement of the fireplace’s ability to convert fuel to heat over a longer period of time including cycling on and off time period.
Design Standard Features
Traditional or Birch log set (Sold separately – one required for installation)
Screen Front
For options and pictures, look at the Nordik brochure under the Manuals & Brochures tab.
Required Design Features
Screen Front
For options and pictures, look at the Nordik brochure under the Manuals & Brochures tab.
Optional Features:
Chicago Brick Refractory
Ledgestone Refractory
Herringbone Refractory
Black Glass Panels
Required for Installation:
1 Piece Shroud (Standard or custom size)